Use standard of toggle switch manufacturer

2022/5/14
When we develop a new toggle switch and socket, we will do many feasibility experiments to ensure the safety of the switch and socket, which is related to life and should not be careless.




1. Weldability test



The top of the terminal is immersed in the solder pool for 1mm, the temperature is 230 ¡À 5 ¡æ, and the time is 3 ¡À 0.5s

be careful:

(1) The welding time shall be less than 3 seconds

(2) The welding area should be more than 80%

2. Welding resistance test

When welding in the welding furnace, the temperature shall be controlled at 260 ¡À 5 ¡æ, the furnace passing time shall be 3 ¡À 0.5 seconds, and the thickness of the substrate shall be 1.0 mm. When welding by hand, the temperature shall be controlled at 320 ¡À 5 ¡æ, and the time shall be 3 ¡À 0.5 seconds

Requirements: the body must be free of deformation and meet the requirements of mechanical and electrical energy

3. Life test

No load: the operator shall conduct 100000 cycles of no-load test at the frequency of 60 times per minute.

requirement:

(1) The contact resistance shall not exceed 200m ¦¸

(2) Others are satisfied with mechanical and electrical performance

4. Heat resistance test

Place it at 85 ¡À 2 ¡æ for 96 hours, and then place it at normal room temperature for 1 hour

Requirements: no abnormal appearance, meet the mechanical and electrical performance

5. Cold resistance test

Place at 40 ¡À 2 ¡æ. When the relative humidity is 90 ~ 96%, the sample shall be tested after being placed in the normal environment for 1 hour.

Requirements: no abnormal appearance, meeting the mechanical and electrical performance

6. Humidity test

Place at 40 ¡À 2 ¡æ. When the relative humidity is 90 ~ 96%, the sample shall be tested after being placed in the normal environment for 1 hour.

Requirements: the appearance is normal and meets the mechanical and electrical performance
Home Products News Contact