Method for checking poor contact of light touch membrane switch

Time:2022/3/5Author:adminClick: 569
1、 The body is 1.5mm away from the molten solder, and then inquire with a 3-10x magnifying glass. Some should be tinned and lubricated. Only a small amount of loose defects such as non moist or weak moist pinholes are allowed, and these defects do not appear in the same direction. In accordance with the additional voltage and current specified in the light touch switch specification, the on-off condition of the circuit can be checked through the indicator light, and the contact resistance test method can also be used to check.



2、 The on-off of the switch shall be accurate and clear, the operation cycle switch shall operate smoothly without jamming, and the circuit change shall be normal. Is the contact between the movable arm of the adjustable resistance touch switch and the resistor excellent. Measure both ends of "1" and "2" (or "2" and "3") with the ohm gear of the multimeter, and turn the rotating shaft of the adjustable resistance counterclockwise to the position close to "off". At this time, the smaller the resistance value, the better. Gradually rotate the shaft handle clockwise, the resistance value should gradually increase, and the pointer in the meter should move smoothly. When the shaft handle is rotated to the pole orientation "3", the resistance value shall be close to the nominal value of the adjustable resistance. If the pointer of the multimeter jumps during the rolling process of the shaft handle of the adjustable resistance, it indicates that the movable contact has the disadvantage of poor contact.